MiVoice Business: Hardware
Indicates there is a problem with the fans, power supplies, or system temperature.
The minor threshold is 100.
Possible Cause |
Corrective Action |
|---|---|
MSP430 hardware failure. MSP430 Upgrade failure. |
When convenient, attempt to recover by shutting down the system using the SHUTDOWN maintenance command. After 60 seconds, power down the system. Leave the system powered down for 30 seconds and then the system power up. Follow corrective action for MSP430 Image alarm. If the problem persists, arrange for system repair. |